All,
I am in the process of planning & designing my solar system for my home. Based on my usage over the last 3 plus years, I have decided to go with 20 panel system (5.1 KW if I use 255W panels) which will produce approximately 7500KwH per year (my usage is around 7600 to 7700KwH). Planning to install it myself, but may get the design/permit service done by someone (online I saw some for $300 to $500). Have a licensed electrician for connection/inspection part.
My system will be: 20 255W panels (thinking of renesola) + M215 enphase. Will have 3 circuits (roof 1, 2, 3 areas) with 8+10+2 panels. I have to learn a few more details before going for the design. I plan to run the conduit in the attic.
Have couple of questions regarding the wiring of the three circuits.
1. The roof 1 area (8 panels) is about 15 to 20 feet away from roof 2 area (10 panels) & roof 2 area (2 panels) is about 6 or 8 feet away. Should I bring the three circuits to the attic separately & then use a AC combiner box in the attic? This will literally make no conduit visible on the roof. I can put the three 'junction boxes' just under the panel/run the conduit into the attic. OR should I run some conduit on the roof (from roof 1 area to roof 2 area, then roof 2 to roof 3 area & then put a combiner near roof 3 area/then go to the attic)? I have hard time deciding on this. OR will the design/permit service provide diagrams that will show the details? (I will check with them but I want to know/learn myself first!)
2. I assume the three circuits will be connected in parallel? (240V AC coming out of each circuit). is that correct. Using a SOLADeck AC/DC combiner box for 2 or 3 branches.
Suggestions on places to buy the panels/inverters will be great.
Thanks for your suggestions.
I am in the process of planning & designing my solar system for my home. Based on my usage over the last 3 plus years, I have decided to go with 20 panel system (5.1 KW if I use 255W panels) which will produce approximately 7500KwH per year (my usage is around 7600 to 7700KwH). Planning to install it myself, but may get the design/permit service done by someone (online I saw some for $300 to $500). Have a licensed electrician for connection/inspection part.
My system will be: 20 255W panels (thinking of renesola) + M215 enphase. Will have 3 circuits (roof 1, 2, 3 areas) with 8+10+2 panels. I have to learn a few more details before going for the design. I plan to run the conduit in the attic.
Have couple of questions regarding the wiring of the three circuits.
1. The roof 1 area (8 panels) is about 15 to 20 feet away from roof 2 area (10 panels) & roof 2 area (2 panels) is about 6 or 8 feet away. Should I bring the three circuits to the attic separately & then use a AC combiner box in the attic? This will literally make no conduit visible on the roof. I can put the three 'junction boxes' just under the panel/run the conduit into the attic. OR should I run some conduit on the roof (from roof 1 area to roof 2 area, then roof 2 to roof 3 area & then put a combiner near roof 3 area/then go to the attic)? I have hard time deciding on this. OR will the design/permit service provide diagrams that will show the details? (I will check with them but I want to know/learn myself first!)
2. I assume the three circuits will be connected in parallel? (240V AC coming out of each circuit). is that correct. Using a SOLADeck AC/DC combiner box for 2 or 3 branches.
Suggestions on places to buy the panels/inverters will be great.
Thanks for your suggestions.
Comment