Hello all,
This is my first post. I've been reading through the forum and have seen some similar posts answered but my situation is a bit tricky. I took over an off grid solar system in Central America. I wasn't here when it was installed, and the installer hasn't left any manuals or wiring charts, so I've been trying to reverse engineer the whole system. So, I have a few questions and any help would be appreciated.
We have 30 x 250-watt (38W peak efficiency) solar panels setup in three sets of 10. Each one of these chains of 10 panels is hooked up to one 60-amp charge controller and runs to a battery bank. The battery bank is comprised of 48 x 12v, 200Ah AGM batteries. They are setup as 4 batteries in series to get to 48V and then linked in parallel. Each charge controller (3) is wired to a bank of 16 batteries, or 4 chains of 4 batteries and then these three smaller banks are linked together in parallel to make the whole battery bank. Correct me if I'm wrong, but this would give a battery bank of 48V and 2,400Ah = 115.2kWh. 4 x 12V in series would give 48V and remain at 200Ah and then 12 of these 48V sets would give the 2,400Ah.
Other possibly useful information:
Solar panel's Imp is 8.39A, VMP is 30.4V and maximum system voltage for the panels is 1000V.
I know this might be a little all over the place. If something isn't clear, please let me know and I'll re-explain it more clearly.
Thanks in advance for any help!
Sashaky
This is my first post. I've been reading through the forum and have seen some similar posts answered but my situation is a bit tricky. I took over an off grid solar system in Central America. I wasn't here when it was installed, and the installer hasn't left any manuals or wiring charts, so I've been trying to reverse engineer the whole system. So, I have a few questions and any help would be appreciated.
We have 30 x 250-watt (38W peak efficiency) solar panels setup in three sets of 10. Each one of these chains of 10 panels is hooked up to one 60-amp charge controller and runs to a battery bank. The battery bank is comprised of 48 x 12v, 200Ah AGM batteries. They are setup as 4 batteries in series to get to 48V and then linked in parallel. Each charge controller (3) is wired to a bank of 16 batteries, or 4 chains of 4 batteries and then these three smaller banks are linked together in parallel to make the whole battery bank. Correct me if I'm wrong, but this would give a battery bank of 48V and 2,400Ah = 115.2kWh. 4 x 12V in series would give 48V and remain at 200Ah and then 12 of these 48V sets would give the 2,400Ah.
- Does this make the most sense as a setup?
- Do the backflow diodes make the most sense as the issue? My thinking is, they're discharging when the sun goes down and the LED lights in the inverter screen blew out, which are the most common indicators of a non-functioning blocking diode.
- I've never installed a backflow diode but I'm wondering if I can install 3 backflow diodes where each set of 10 solar panels come together in a junction box so that I don't have to install 30 diodes or replace the PV junction box.
Other possibly useful information:
Solar panel's Imp is 8.39A, VMP is 30.4V and maximum system voltage for the panels is 1000V.
I know this might be a little all over the place. If something isn't clear, please let me know and I'll re-explain it more clearly.
Thanks in advance for any help!
Sashaky
Comment