I currently do this at my camp and an able to put about 3KWH into making hot water consistently. That is from 900W of panels connected as a 36V string and about a 52V power point. Keep in mind that this is only the excess power after everything else is powered. There are two tanks, 10gal with 2000W 125V element and 20gal with 1500W 125V element. These are connected in series with the 10 gallon as the final. That allows fast heating in the morning and can usually get to 45C by 10am. Either heater or both can be on. A couple FET control each heating element by PWM from a UNO. FET are driven at low frequency via a simple opto isolator driver. It operates from a simple program that monitors the fixed power point voltage of the panels. Really no need to track. If voltage is over the setpoint, the PWM counts up. And down if lower. You could do the same with a TL495 switching regulator chip. Controls are powered by wall warts. A good percentage of them work easily at 50V. The whole secret is a large capacitor bank that stores panel power between on pulses. I use an old TURNIGY 130A to record power. Variants of these sell for only $10. This picture is my power shed that holds the two tanks and all my electronics.
I also tried a variant of this at home using cheap ebay boost converters. Boost converter runs at full bore and the input voltage is monitored with uno driving a FET. Even just a 250W panel is quite effective since normal water heater losses are about 150W.
I also tried a variant of this at home using cheap ebay boost converters. Boost converter runs at full bore and the input voltage is monitored with uno driving a FET. Even just a 250W panel is quite effective since normal water heater losses are about 150W.
Comment